Bolt Root and Tensile Stress Area
Root area and tensile stress area per bolt size — metric M 14 to M 100 (coarse series) and inch 1/2 to 4 in. — the two areas every bolt load-capacity and pretension calculation starts from.
Last updated: 2026-11
Reference data
Two areas matter when you size a bolted joint, and they are not the same. The tensile stress area is the effective area a threaded bolt carries tension over: it blends the thread root diameter and pitch diameter so that the weaker threaded section and the shank can be compared on one number. The root area is the smaller area at the thread root itself — the section where fatigue cracks start — and conservative calculations size the bolt on it. This reference tabulates both per nominal size: metric M 14 through M 100 on the coarse series (e.g. M24-3: root 317.3 mm 2, tensile stress 352.5 mm 2) and inch sizes 1/2 through 4 in. with their threads-per-inch (e.g. 1-8: root 0.5509 in 2, tensile stress 0.6057 in 2). Above M 39 / 1 in. the coarse pitch stays constant while diameter grows, so the areas climb steeply — root area from 976.6 mm 2 at M 39 to 7253 mm 2 at M 100. Use the tensile stress area with the material's proof or yield strength for joint pretension, the root area where fatigue governs. Head dimensions, lengths and finishes are not tabulated here — per RFQ against the bolt's dimensional standard.
| Metric range | M 14 to M 100, coarse series designations (M14-2 ... M100-3), 21 sizes |
|---|---|
| Inch range | 1/2 to 4 in., 13-8 threads per inch, 21 sizes |
| Columns per size | Root area and tensile stress area, mm 2 (metric) / in. 2 (inch) |
| Worked example | M 16: root 141.0 mm 2, tensile stress area 156.7 mm 2; 3/4-10: root 0.3019 in 2, tensile stress area 0.3345 in 2 |
| Not tabulated | Property-class strengths to pair with the areas, head dimensions, lengths, finishes — per RFQ |
| Bolt Size, Basic Thread Designation [Notes(1),(2)] | Root Area, mm 2 | Tensile Stress Area, mm 2 [Note(3)] |
|---|---|---|
| M14-2 | 102.1 | 115.4 |
| M16-2 | 141.0 | 156.7 |
| M20-2.5 | 220.4 | 244.8 |
| M24-3 | 317.3 | 352.5 |
| M27-3 | 419.1 | 459.4 |
| M30-3 | 535.0 | 580.4 |
| M33-3 | 665.1 | 715.6 |
| M36-3 | 809.3 | 864.9 |
| M39-3 | 976.6 | 1028 |
| M42-3 | 1140 | 1206 |
| M45-3 | 1327 | 1398 |
| M48-3 | 1527 | 1604 |
| M52-3 | 1817 | 1900 |
| M56-3 | 2132 | 2222 |
| M64-3 | 2837 | 2940 |
| M70-3 | 3432 | 3545 |
| M76-3 | 4083 | 4207 |
| M82-3 | 4791 | 4925 |
| M90-3 | 5822 | 5970 |
| M95-3 | 6518 | 6674 |
| M100-3 | 7253 | 7418 |
| Bolt Size, in. | Threads per Inch | Root Area, in. 2 | Tensile Stress Area ,in. 2 [Note(3)] | |
|---|---|---|---|---|
| 1/2 | 13 | 0.1257 | 0.1419 | |
| 5/8 | 11 | 0.2017 | 0.2260 | |
| 3/4 | 10 | 0.3019 | 0.3345 | |
| 7/8 | 9 | 0.4192 | 0.4617 | |
| 1 | 8 | 0.5509 | 0.6057 | |
| 1 - 1/8 | 8 | 0.7276 | 0.7905 | |
| 1 - 1/4 | 8 | 0.9289 | 0.9997 | |
| 1 - 3/8 | 8 | 1.155 | 1.234 | |
| 1 - 1/2 | 8 | 1.405 | 1.492 | |
| 1 - 5/8 | 8 | 1.680 | 1.775 | |
| 1 - 3/4 | 8 | 1.979 | 2.082 | |
| 1 - 7/8 | 8 | 2.303 | 2.414 | |
| 2 | 8 | 2.652 | 2.771 | |
| 2 - 1/4 | 8 | 3.422 | 3.557 | |
| 2 - 1/2 | 8 | 4.291 | 4.442 | |
| 2 - 3/4 | 8 | 5.258 | 5.425 | |
| 3 | 8 | 6.324 | 6.506 | |
| 3 - 1/4 | 8 | 7.487 | 7.686 | |
| 3 - 1/2 | 8 | 8.748 | 8.963 | |
| 3 - 3/4 | 8 | 10.11 | 10.34 | |
| 4 | 8 | 11.57 | 11.81 |
How to use it
- The areas are geometry, not strength — pick the strength from the property class or material spec your joint calls out (ISO 898-1, ASTM A307/A325/A490, etc.) and multiply. When you send an RFQ for high-strength or fatigue-critical bolts, state the size, the stress area basis your calculation used, and the required class so the supply can be quoted against a matching certificate
These figures are engineering reference data, not a stocked-range claim. Parts manufactured or sourced to the standards named here are quoted on request — send an RFQ with your sizes, grades and quantities and the quote carries the confirmed schedule and documents.
Frequently asked questions
Which area should I use for a bolted-joint calculation — root or tensile stress area?
For static pretension and clamp-load calculations, the tensile stress area: it is the standard effective area for a threaded bolt in tension and is what torque-to-preload tables assume. For fatigue assessment, work from the root area, because the root is the stress-concentrated section where cracks initiate — comparing the root area of the threaded section against the full shank area also tells you whether the bolt will yield in the shank or at the threads first. The two columns in this table are roughly 8-10% apart in the metric range (e.g. M 16: 141.0 vs 156.7 mm 2), so using the wrong one shifts a capacity estimate by that much. If the joint is governed by shear, bearing or a code basis (AISC, Eurocode, BS 5950 legacy data on this site), use that code's own areas and rules instead.
Why does the inch table stop changing threads per inch above 1 in.?
Because the tabulated inch series is the coarse 8-UNC thread from 1 in. upward: large-diameter coarse threads keep 8 threads per inch all the way to 4 in., so only the areas grow with diameter (root 0.5509 in 2 at 1 in. against 11.57 in 2 at 4 in.). This matches how stock inch bolts are supplied — an 8-UN thread on large coarse-series sizes. If your joint specifies 8-UN specifically, fine-pitch (UNF) or 8-thread heavy-duty practice, confirm the thread callout on the drawing and quote the size with it; this page carries the tabulated series only, and special pitches are per RFQ.