BS EN ISO 898-1:2013 Screw Loads (Proof, Tensile, Tightening Torque)

Per-size screw loads for ISO metric threads M6-M36 at property classes 4.6/8.8/10.9/12.9: nominal tensile stress area, minimum ultimate tensile load Fm,min, proof load Fp, and the source's estimated tightening torque — the load-side companion to the stress/hardness property-class table.

Last updated: 2026-11

BS EN ISO 898-1:2013 Screw Loads (Proof, Tensile, Tightening Torque) — engineering reference
Illustrative image redrawn from real product references — not a photograph of stocked items.

Reference data

The property-class table says what a class is; this collected page says what that means in kilonewtons for a specific thread size. Four ladders run across M6 to M36 in the standard coarse pitches: the nominal tensile stress area As,nom (20.1 mm2 at M6 up to 817 mm2 at M36), then for classes 4.6, 8.8, 10.9 and 12.9 the minimum ultimate tensile load (a 12.9 M12 must carry 103 kN before fracture; the same thread at 4.6 only 33.7 kN), the proof load Fp the joint is rated to sit at permanently (81.8 kN at 12.9 M12), and the source's estimated tightening torque — 142.8 N·m at 10.9 M12, 2999 N·m at 12.9 M36 — which it computes from the proof loads at assumed friction, not from the standard: read it as a sensible assembly-starting estimate, not an acceptance value, and use a torque-tension study for anything critical. The M22 column is a reminder that stress area is not linear in diameter: M22 at 2.5 pitch (303 mm2) sits between M20 and M24, and the fine-pitch variants are not tabulated here at all.

Standard BS EN ISO 898-1:2013 — mechanical properties of fasteners made of carbon steel and alloy steel, part 1: bolts, screws and studs with specified property classes (coarse thread, M6-M36)
Stress area As,nom M6: 20.1 / M8: 36.6 / M10: 58.0 / M12: 84.3 / M14: 115 / M16: 157 / M20: 245 / M22: 303 / M24: 353 / M30: 561 / M36: 817 mm2 at pitches 1.0-4.0 mm
Min. ultimate tensile load Fm,min Class 4.6: 8.04 kN (M6) to 327 kN (M36); 8.8: 16.1 to 678; 10.9: 20.9 to 850; 12.9: 24.5 to 997 kN
Proof load Fp Class 4.6: 4.52 kN (M6) to 184 kN (M36); 8.8: 11.6 to 490; 10.9: 16.7 to 792; 12.9: 19.5 to 792/997 ladder — the permanent-joint rating
Estimated tightening torque (source) 4.6: 4.6 N·m (M6) to 1126 N·m (M36); 8.8: 11.8 to 2999; 10.9: 17.0 to 4149; 12.9: 19.5 to 792 (M36) — source estimate at assumed friction, not an ISO requirement
Not tabulated Fine-pitch threads, sizes above M36, shear loads, fatigue, nut-side loads (ISO 898-2), torque-tension coefficients (K factor) — per RFQ
BS EN ISO 898-1:2013 — thread pitch and nominal tensile stress area M6-M36Pitch in mm; stress area As,nom in mm2. Verification: live-DOM re-dump verify 2026-11-02 (batch x141 sample, 252 cells strict-equal across the four tables).
ThreadPitch (mm)Stress Area As,nom (mm2)
M61.0020.1
M81.2536.6
M101.5058.0
M121.7584.3
M142.00115
M162.00157
M202.50245
M222.50303
M243.00353
M303.50561
M364.00817
BS EN ISO 898-1:2013 — minimum ultimate tensile load Fm,min (kN) by property class and sizeLoads in kN; size ladders run across the columns with the class ladder down the rows; the trailing empty column in the stacked header is the source's own, carried verbatim.
Property ClassMinimum Ultimate Tensile Load Fm,min (kN)
M6M8M10M12M14M16M20M22M24M30M36
4.68.0414.623.233.746.062.898.0121141224327
8.816.129.246.467.492.0125203252293466678
10.920.938.160.387.7120163255315367583850
12.924.544.670.8103140192299370431684997
BS EN ISO 898-1:2013 — proof load Fp (kN) by property class and sizeLoads in kN; layout conventions as the Fm,min table.
Property ClassProof Load Fp (kN)
M6M8M10M12M14M16M20M22M24M30M36
4.64.528.2413.019.025.935.355.168.279.4126184
8.811.621.233.748.966.791.0147182212337490
10.916.730.448.170.095.5130203252293466678
12.919.535.556.381.8112152238294342544792
BS EN ISO 898-1:2013 — estimated tightening torque (N·m) by property class and sizeTorques in N·m as estimated by the source (friction-estimate values, not a standard ladder); layout conventions as the Fm,min table. The decimal-point mixed notation (158.7 / 247.5 / 942.5) is the source's own.
Property ClassEstimated Tightening Torque (N·m)
M6M8M10M12M14M16M20M22M24M30M36
4.64.611.222.138.861.696.01872553246431126
8.811.828.857.399.8158.7247.550068186517192999
10.917.041.381.8142.8227.3353.6690942.5119523774149
12.919.948.395.7166.9266.6413.48091100139527744847

How to use it

  • These ladders are carbon/alloy steel property-class values only — stainless A2/A4 runs on the ISO 3506 equivalent classes and does not map 1:1. For torque-critical joints the estimated torque column is a starting point: friction conditions (lubricated vs as-received) move the achieved preload by tens of percent, so specify the lubrication state and verification method on the RFQ

These figures are engineering reference data, not a stocked-range claim. Parts manufactured or sourced to the standards named here are quoted on request — send an RFQ with your sizes, grades and quantities and the quote carries the confirmed schedule and documents.

Frequently asked questions

Why is the proof load, not the tensile load, the number to size a joint against?

The proof load Fp is the load the fastener must carry permanently without permanent set — take a bolt to its proof load, unload it, and it must measure as it did before. The minimum ultimate tensile load Fm,min is where it finally breaks. A joint works at some fraction of Fp (the tightening step itself consumes most of it as preload), so the usable design envelope ends near the proof-load ladder, while the tensile ladder is reserve for overload and the tightening-estimate column is assembly tooling, not joint capacity. The collected tables keep the three apart per class and size — a 10.9 M16 is 130 kN proof, 163 kN minimum ultimate, and an estimated 227.3 N·m to tighten — and mixing any two of them in a specification is the classic procurement error.

How should the estimated tightening torque column be used — and trusted?

As an estimate, exactly as the source labels it. It back-computes a wrench torque from the proof-load ladder at assumed thread and bearing friction, which is why an 8.8 M12 reads 57.3 N·m while a 10.9 of the same size reads 142.8 N·m — the geometry is identical, only the target preload changes. Real achieved preload scatters widely with friction: the same torque on a lubricated versus dry thread can differ by a third or more, and large sizes (the ladder reaches 4149 N·m at 10.9 M36) are beyond accurate torque control anyway. Use the column for tool selection and sanity checks on non-critical joints; for verified preload, specify angle control, hydraulic tensioning, or a measured K-factor on the RFQ.