TCH & TCHS Thin-Sheet Self-Clinching Studs (Non-Flush)

Non-flush self-clinching studs for very thin sheet — TCH heat-treated carbon steel and TCHS 300-series stainless — for panels from 0.020 in. (0.5 mm), unified #4-40 to #10-32 and metric M3 to M5, with controlled mounting holes +.003/-.000 and a full installation/performance table by thread code.

Last updated: 2026-11

Request a Quote

TCH & TCHS Thin-Sheet Self-Clinching Studs (Non-Flush) in an industrial setting
Illustrative image redrawn from real TCH & TCHS Thin-Sheet Self-Clinching Studs (Non-Flush) product references — not a photograph of stocked items.

Specifications

TCH and TCHS are self-clinching studs for panels too thin for standard flush-head clinching hardware: they install in sheet as thin as 0.020 in. (0.5 mm) and, by design, the head sits slightly above the panel surface instead of flush. Pressed in with a squeezing force, the stud becomes a captivated, non-rotating external thread in the panel — no weld, no insert, and the mating nut can be run on without holding the stud. TCH is heat-treated carbon steel (zinc clear); TCHS is 300-series stainless steel (passivated per ASTM A967). Threads are external 2A per ANSI B1.1 (6g per ANSI/ASME B1.13M for metric), and the panels are cold-rolled steel or 5052-H34 aluminum: TCH installs into panels of Rockwell B-80 or less, TCHS into HRB 70 or less. A typical designation reads TCH 632-12: carbon-steel stud, #6-32, 12 (x 1/16 in. length code). One installation caution is printed on the collected sheet and worth repeating: do not over-squeeze.

Series TCH (heat-treated carbon steel, zinc clear) — panels HRB 80 or less; TCHS (300-series stainless, passivated per ASTM A967) — HRB 70 or less; panel materials cold-rolled steel or 5052-H34 aluminum
Threads External 2A per ANSI B1.1 (6g per ANSI/ASME B1.13M metric): #4-40 (code 440), #6-32 (632), #8-32 (832), #10-24 (1024), #10-32 (1032); M3 x 0.5 (M3), M4 x 0.7 (M4), M5 x 0.8 (M5)
Minimum sheet thickness 0.020 in. unified; 0.5 mm metric — the stud installs into sheet well below the standard flush-series minimums
Head style Non-flush: the head projects above the panel surface when installed (this is the design intent, not a defect)
Mounting hole (by thread) #4-40: .111, #6-32: .137, #8-32: .163, #10-24 and #10-32: .189 — each +.003/-.000 in.; metric M3/M4/M5: 3.0/4.0/5.0 mm +.08/-.00
Length ladders Inch .250–1.50 in. (codes -4 to -24 by thread; ±.015 in.); metric 6–38 mm (codes -6 to -38; ±.4 mm). A dagger on some codes marks the source catalog's own stocking, not this offer
Performance (sampled, .025 in. steel panel) #4-40: 1500 lbs installation force, 100 lbs pushout, 8 in.-lbs torque-out (max nut-tightening 5 in.-lbs); #6-32: 2500 / 110 / 16 (9 in.-lbs); #8-32: 2700 / 120 / 26 (17 in.-lbs); #10-24 and #10-32: 3000 / 130 / 28 (24 and 27 in.-lbs max tightening)
Performance (sampled, .020 in. aluminum panel) #4-40: 1200 / 45 / 7; #6-32: 1500 / 50 / 8; #8-32: 2200 / 60 / 11; #10-24 and #10-32: 2500 / 65 / 14 — installation force / pushout lbs / torque-out in.-lbs; values are the stainless-stud basis (steel may be higher)
Installation caution Printed on the collected sheet: "Do not over squeeze!" — squeeze only until the head seats against the panel
MOQ / lead time Not owner-confirmed for this family — confirmed at quotation

Materials

  • Heat-treated carbon steel, zinc clear (TCH)
  • 300-series stainless steel, passivated per ASTM A967 (TCHS)

Ordering & documentation

Documents

Shipments of TCH & TCHS Thin-Sheet Self-Clinching Studs (Non-Flush) are backed by Mill Test Certificate (MTC), Dimensional Report, Salt Spray Test Report on request, with full batch traceability from raw material to finished product. Quality management for TCH & TCHS Thin-Sheet Self-Clinching Studs (Non-Flush) orders follows the owner-confirmed compliance list: ISO 9001:2015, RoHS, REACH. Exact document sets are confirmed on the order.

Quotation

  • The product family (TCH & TCHS Thin-Sheet Self-Clinching Studs (Non-Flush)), product standard/designation and drawing or part number.
  • The dimensions that apply to this part — such as size, pitch, length, thickness, fit, grip or groove geometry.
  • Material/grade, heat-treatment condition and surface finish, together with the service environment.
  • Quantity per size, delivery destination and required test or traceability documents.

Sample & supply

Minimum order quantities and lead times for tch & tchs thin-sheet self-clinching studs (non-flush) are confirmed at quotation — send series, thread size and parent sheet thickness on the RFQ and the quote will carry a firm schedule; sample availability is confirmed with the quotation.

Storage & shipping

TCH & TCHS Thin-Sheet Self-Clinching Studs (Non-Flush) are packed for export and shipped factory-direct to buyers in Europe, Asia, the Americas and the Middle East. Store tch & tchs thin-sheet self-clinching studs (non-flush) dry and protected until installation, and keep coated parts in their packaging until use; specific packing and preservation requirements can be stated on the order and confirmed at quotation.

Frequently asked questions

When do I need TCH/TCHS instead of a standard flush self-clinching stud?

When the panel is thinner than the flush-head series can grip. TCH/TCHS install into sheet as thin as 0.020 in. (0.5 mm), where a flush clinch head would not find enough material to cold-flow into. The trade-off is cosmetic and functional at once: the head sits slightly proud of the panel by design, and the collected sheet's pushout/torque-out figures at that thickness (for example 110 lbs pushout and 16 in.-lbs torque-out for a #6-32 in 0.025 in. steel) are strong for the gauge. If your panel is at standard thickness and the head must sit flush, quote the FH/FHS series instead.

What do the performance figures assume?

The collected table states its values are based on stainless-steel studs, with steel-stud values potentially higher, per thread code at two named sheet conditions: 0.020 in. aluminum (HRB 28) and 0.025 in. steel (HRB 52). For example a #10-32 shows 3000 lbs installation force, 130 lbs pushout and 28 in.-lbs torque-out in the steel condition. Your panel and thickness move these numbers — ask for the row matching your exact sheet at quotation.

What should an RFQ for these self-clinching standoffs state?

State the series (CFSO steel, CFSOS stainless, or CFSOA aluminum), thread size (for example #10-32 or M4 x 0.7), body size (small or large), nominal length L, sheet material, thickness and hardness, and quantity per size — plus destination country. Commercial terms are confirmed at quotation.

Request a Quote

Get factory-direct pricing from the manufacturer.

What to include in your TCH & TCHS Thin-Sheet Self-Clinching Studs (Non-Flush) inquiry

  • ✓ Identify the clinch-nut, stud or standoff series and the internal thread size.
  • ✓ Specify parent-sheet material, hardness and actual thickness, not gauge alone.
  • ✓ Provide prepared-hole diameter, edge distance and hole-to-hole spacing from the panel drawing.
  • ✓ State locking/non-locking requirement, installation press/tooling and any push-out or torque-out acceptance data.
  • ✓ Factory-direct pricing for your TCH & TCHS Thin-Sheet Self-Clinching Studs (Non-Flush)
  • ✓ Standard and custom specifications
  • ✓ Factory-direct export to buyers in Europe, Asia, the Americas and the Middle East
  • ✓ Full fastener family support

We use your details only to answer this inquiry — see our Privacy notice for everything the form collects.