Flanged Joint Heavy Hex Bolts (ANSI/AWWA C115/C110) — Per-Pipe-Size Chart
Heavy hex bolts for flanged ductile-iron and gray-iron joints, aligned with ANSI/AWWA C115/A21.15 and C110/A21.10 — the collected per-pipe-size chart: bolt size, length and quantity per flanged joint for 3 – 64 in pipe.
Last updated: 2026-11
Specifications
Flanged joints in iron waterworks systems — the bolted face-to-face connection covered by ANSI/AWWA C115/A21.15 for ductile-iron flanges and C110/A21.10 for gray-iron fittings and valves — use heavy hex bolts in a count and length set by the pipe size, and the collected chart tabulates exactly that: for every nominal pipe size from 3 to 64 in, the number of bolts per joint, their diameter and their length. The ladder is coarse and deliberate: a 3 in joint takes four 5/8 in bolts 2 1/2 in long; by 12 in it is twelve 7/8 in bolts at 4 in; the 1 in diameters appear at 14–16 in; and the largest rows reach fifty-two 1 3/4 in bolts, 9 in long, on 60–64 in pipe. Length tracks the flange hub thickness and the gasket pack of standard-class flanges, which is why it grows roughly with diameter — order by the row unless your assembly stacks non-standard collars or spacers, in which case confirm length at RFQ. The chart prints no torque values for flanged joints (unlike the mechanical-joint T-head companion chart) and no material or coating columns — all per RFQ, with gasket and ring type following the flange class on the drawing.
| Standard alignment | ANSI/AWWA C115/A21.15-99 and C110/A21.10-03 (source statement kept) — flanged joint heavy hex bolts for iron waterworks flanges, fittings and valves |
|---|---|
| Pipe size range | Nominal 3 – 64 in, eighteen pipe-size rows (3 through 64, including the 54 and 64 in sizes absent from the mechanical-joint chart) |
| Tabulated values | Per pipe size: bolt quantity per joint (4 – 52), bolt size (5/8 – 1 3/4 in), bolt length (2 1/2 – 9 in) |
| Units | Size and length in inches |
| Material / coating / torque | Not tabulated by the collected chart — per RFQ (state coating system, flange class and any project torque specification at quotation) |
| Nominal Recommended Pipe Size | Quantity | Size (in) | Length (in) |
|---|---|---|---|
| 3 | 4 | 5/8 | 2 1/2 |
| 4 | 8 | 5/8 | 3 |
| 6 | 8 | 3/4 | 3 1/2 |
| 8 | 8 | 3/4 | 3 1/2 |
| 10 | 12 | 7/8 | 4 |
| 12 | 12 | 7/8 | 4 |
| 14 | 12 | 1 | 4 1/2 |
| 16 | 16 | 1 | 4 1/2 |
| 18 | 16 | 1 1/8 | 5 |
| 20 | 20 | 1 1/8 | 5 |
| 24 | 20 | 1 1/4 | 6 1/2 |
| 30 | 28 | 1 1/4 | 6 1/2 |
| 36 | 32 | 1 1/2 | 7 |
| 42 | 36 | 1 1/2 | 7 1/2 |
| 48 | 44 | 1 1/2 | 8 |
| 54 | 44 | 1 1/2 | 8 1/2 |
| 60 | 52 | 1 3/4 | 9 |
| 64 | 52 | 1 3/4 | 9 |
Materials
- Bolt material and coating specified per RFQ — flanged-joint hardware in buried or exposed waterworks service is usually ordered coated; state the environment and flange class at quotation
Ordering & documentation
Documents
Shipments of Flanged Joint Heavy Hex Bolts (ANSI/AWWA C115/C110) — Per-Pipe-Size Chart are backed by Mill Test Certificate (MTC), Dimensional Report, Salt Spray Test Report on request, with full batch traceability from raw material to finished product. Quality management for Flanged Joint Heavy Hex Bolts (ANSI/AWWA C115/C110) — Per-Pipe-Size Chart orders follows the owner-confirmed compliance list: ISO 9001:2015, RoHS, REACH. Exact document sets are confirmed on the order.
Quotation
- The product family (Flanged Joint Heavy Hex Bolts (ANSI/AWWA C115/C110) — Per-Pipe-Size Chart), product standard/designation and drawing or part number.
- The dimensions that apply to this part — such as size, pitch, length, thickness, fit, grip or groove geometry.
- Material/grade, heat-treatment condition and surface finish, together with the service environment.
- Quantity per size, delivery destination and required test or traceability documents.
Sample & supply
Supply source for Flanged Joint Heavy Hex Bolts (ANSI/AWWA C115/C110) — Per-Pipe-Size Chart: own manufacturing plus qualified outsourcing (per the owner-confirmed scope of supply (own production plus outsourcing)).
Minimum order quantity for flanged joint heavy hex bolts (ansi/awwa c115/c110) — per-pipe-size chart is 1,000–10,000 pieces depending on size (applies to the standard sizes and finishes for flanged joint heavy hex bolts (ansi/awwa c115/c110) — per-pipe-size chart; mixed, special or custom variants are quoted — final commercial terms per quotation) Stock items for flanged joint heavy hex bolts (ansi/awwa c115/c110) — per-pipe-size chart run 3–7 days. High-strength and custom parts for flanged joint heavy hex bolts (ansi/awwa c115/c110) — per-pipe-size chart run 15–25 days. Quantities or variants of flanged joint heavy hex bolts (ansi/awwa c115/c110) — per-pipe-size chart outside the standard range are confirmed at quotation.
Storage & shipping
Flanged Joint Heavy Hex Bolts (ANSI/AWWA C115/C110) — Per-Pipe-Size Chart are packed for export and shipped factory-direct to buyers in Europe, Asia, the Americas and the Middle East. Store flanged joint heavy hex bolts (ansi/awwa c115/c110) — per-pipe-size chart dry and protected until installation, and keep coated parts in their packaging until use; specific packing and preservation requirements can be stated on the order and confirmed at quotation.
Frequently asked questions
Why does the flanged-joint chart have no torque column when the mechanical-joint chart does?
Because the two joints seal differently, and the collected charts reflect that. A mechanical joint compresses a molded gasket pack inside a gland, and the AWWA-aligned chart prints a torque range per pipe size as part of the assembly instruction — the gland needs a defined, repeatable compression to seal. A flanged joint seals through the compression of a flat ring gasket between two flange faces, where the assembly target is normally stated as a bolt stress, a torque value in the project specification, or a tightening pattern, and it depends on the flange class, gasket material and service — not on pipe size alone. There is no single pipe-size-keyed torque ladder the chart could honestly print. Practically: take bolt count, diameter and length from the row for your pipe size; take the torque from the governing specification or the flange/gasket manufacturer; and if the project is silent, that question goes into the RFQ alongside material and coating — the dimension chart answers geometry, not assembly engineering.
What is the MOQ and lead time for this bolt type?
The minimum order quantity for Flanged Joint Heavy Hex Bolts (ANSI/AWWA C115/C110) — Per-Pipe-Size Chart is 1,000–10,000 pieces depending on size. Stock items of Flanged Joint Heavy Hex Bolts (ANSI/AWWA C115/C110) — Per-Pipe-Size Chart ship in 3–7 days; high-strength and custom parts in 15–25 days. Common sizes of Flanged Joint Heavy Hex Bolts (ANSI/AWWA C115/C110) — Per-Pipe-Size Chart are widely stocked; confirm the exact schedule against quantity and size mix at quotation.
What is the MOQ and lead time for Flanged Joint Heavy Hex Bolts (ANSI/AWWA C115/C110) — Per-Pipe-Size Chart?
Orders under this designation have a minimum order quantity of 1,000–10,000 pieces depending on size. Stock items ship in 3–7 days; high-strength and custom parts in 15–25 days. Final commercial terms are confirmed per quotation.
What should an RFQ for Flanged Joint Heavy Hex Bolts (ANSI/AWWA C115/C110) — Per-Pipe-Size Chart state?
State the full designation (Flanged Joint Heavy Hex Bolts (ANSI/AWWA C115/C110) — Per-Pipe-Size Chart), thread size and pitch or diameter, length or head dimension, finish, quantity per size, plus the destination country and any required certificate such as a mill test report per EN 10204 3.1; dimensions and schedule for this designation are confirmed with the quotation.
Related knowledge
- What Bolt Property Classes 8.8, 10.9 and 12.9 Encode — and When High Strength Stops Being the Right Choice
- Bolt Grade Selection: ISO 898-1 8.8/10.9/12.9 vs ASTM A307 and A325
- 8.8 vs 10.9 vs 12.9 Bolts: Strength, Hardness and Cost — What the Evidence Settles
- Calculating Bolt Preload and Clamp Force: Torque, Friction and Tightening Method
- How to Determine Tightening Torque and Choose a Tightening Method for a Bolted Joint
- Fastener Failure Modes: Which Fatigue, Creep and SCC Controls the Evidence Supports
- Hydrogen Embrittlement in High-Strength Bolts: Which Grades Need Controls, Which Coatings and Baking Schedules Are Acceptable, and What to Require Before the RFQ
Request a Quote
Get factory-direct pricing from the manufacturer.
What to include in your Flanged Joint Heavy Hex Bolts (ANSI/AWWA C115/C110) — Per-Pipe-Size Chart inquiry
- ✓ Name the bolt standard and product form, then give nominal diameter, pitch, length and threaded length.
- ✓ State the applicable property class or material grade, head style, and coating or finish.
- ✓ Identify the mating nut/washer and the joint duty; include any specified preload, tightening method or friction condition.
- ✓ Give quantity per size, destination and required material or inspection certificates.
- ✓ Factory-direct pricing for your Flanged Joint Heavy Hex Bolts (ANSI/AWWA C115/C110) — Per-Pipe-Size Chart
- ✓ Standard and custom specifications
- ✓ Factory-direct export to buyers in Europe, Asia, the Americas and the Middle East
- ✓ Full fastener family support