U-Bolts by Pipe Size (IFI-136 Waterworks Series)

U-bolts sized by nominal pipe size, 1/2 through 36 in, in the waterworks series: bolt diameter 1/4–1 in, hook (inside-leg spacing) C 15/16–36 1/8 in, length L 3 1/4–39 11/16 in and thread length T 2 3/8–4 3/4 in per the IFI-136 measuring convention. The pipe clamp and hanger bolt of waterworks and mechanical-joint assemblies.

Last updated: 2026-11

Request a Quote

U-Bolts by Pipe Size (IFI-136 Waterworks Series) in an industrial setting
Illustrative image redrawn from real U-Bolts by Pipe Size (IFI-136 Waterworks Series) product references — not a photograph of stocked items.

Specifications

A U-bolt wraps a pipe and lands on a support: the curved bend rides the pipe barrel, the two legs pass through a clamp, flange or bracket, and nuts on the threaded ends clamp the assembly — which is why the pipe size, not a head standard, is how this bolt is specified. The collected size chart follows the Industrial Fastener Institute IFI-136 measuring convention, and its definitions matter when comparing suppliers' charts: length L runs from the end of the bolt to the inside of the bend, and hook C is the distance between the legs (some drawings show these dimensions from centreline instead — state the convention with the order). The series runs from 1/2 pipe (1/4 in bolt diameter, hook 15/16 in, length 3 1/4 in) up through 36 pipe (1 in bolt diameter, hook 36 1/8 in, length 39 11/16 in), with the thread length T stepping 2 3/8 in at the small end to 4 3/4 in at the large. The collected chart tabulates the thread length but not the thread series, so the UNC/UNF callout is confirmed at quotation. U-bolts outside the charted ladder are made to drawing: state pipe size, hook, length, thread length, diameter and finish. For metric work, the DIN 3570 designation covers U-bolts sized to metric pipe diameters — its table is tabulated below as a separate standard, not a conversion of this inch-based ladder.

Series U-bolts by nominal pipe size, waterworks series, measured per IFI-136
Size range Pipe 1/2 – 36 in; bolt diameter D 1/4 – 1 in; hook C 15/16 – 36 1/8 in; length L 3 1/4 – 39 11/16 in
Dimensions at pipe 1/2 D 1/4 in; C (hook) 15/16 in; L (length) 3 1/4 in; T (thread length) 2 3/8 in
Dimensions at pipe 6 D 5/8 in; C 6 3/4 in; L 9 1/2 in; T 3 3/4 in
Dimensions at pipe 36 D 1 in; C 36 1/8 in; L 39 11/16 in; T 4 3/4 in
Thread Thread length T tabulated per pipe size (2 3/8 – 4 3/4 in); thread series not printed by the collected chart — confirmed at quotation
Measuring convention L = end of bolt to inside of bend; C = distance between legs; D = diameter of one leg (IFI-136, as measured by the collected source)
Materials Steel, stainless steel — grade and finish confirmed at quotation (tenant supply range)
U-bolts by pipe size, waterworks series (pipe 1/2 - 36)All dimensions in inches per the IFI-136 measuring convention: L from bolt end to inside of bend, C as the distance between legs. The collected chart prints no thread-series column — thread series confirmed at quotation.
Nominal pipe size (in)Bolt diameter D (in)C — hook, between legs (in)L — length to inside of bend (in)T — thread length (in)
1/21/415/163 1/42 3/8
3/41/41 1/83 5/162 3/8
11/41 3/83 7/162 3/8
1 1/43/81 11/163 3/42 3/8
1 1/23/8242 1/2
23/82 7/164 1/22 1/2
2 1/21/22 15/165 1/43
31/23 9/165 13/163
3 1/21/24 1/166 5/163
41/24 9/166 13/163
51/25 5/87 13/163
65/86 3/49 1/23 3/4
85/88 3/411 1/23 3/4
103/410 7/813 13/164
127/812 7/816 1/164 1/4
147/814 1/817 5/164 1/4
167/816 1/819 5/164 1/4
18118 1/821 11/164 3/4
20120 1/823 11/164 3/4
24124 1/827 11/164 3/4
30130 1/833 11/164 3/4
36136 1/839 11/164 3/4
DIN 3570 U-bolts — metric sizes 23 to 332 (pipe diameter, clamp breadth, shank, thread, E, H1)Millimetres as printed by the collected DIN 3570 table (decimal commas preserved). This metric designation complements the inch-based IFI-136 waterworks ladder above — it is a separate standard with its own callouts, not a conversion of it.
SizeD1 (pipe dia)B1D2 (shank dia)D3 (thread)E (per source legend: pitch)H1
2320 - 213010M103360
3025 - 26,94010M104070
3830 - 33,74010M104876
4638 - 42,45010M105686
5244,5 - 48,35010M106292
6457 - 60,35012M1276109
8276,15012M1294125
9488,95012M12106138
120108 - 114,36016M16136171
148133 - 139,76016M16164191
176159 - 168,36016M16192217
228216 - 219,17020M20248283
282267 - 2737020M20302334
332318 - 323,97020M20352385
  • The source's legend labels E as "pitch", but the printed E values (33 to 352) scale with size the way a centre distance does; the column is kept here under the source's own legend, not re-interpreted. State the E dimension explicitly and confirm the measuring convention at quotation.
  • The source legend also defines b (thread length), h (height), d2, d3, NW and a, but the rendered table prints none of those letters — it prints D1/B1/D2/D3/E/H1. Only the printed rows are transcribed; per-size thread length is confirmed at quotation.
  • D1 cells are pipe-diameter ranges with decimal commas as printed (e.g. 25 - 26,9); ranges are kept as ranges, not split into min/max.
  • The source lists one material (steel st37); no stainless or finish rows are printed, so material and finish for DIN 3570 parts are confirmed at quotation.

Materials

  • Steel, stainless steel — grade and finish confirmed at quotation (tenant supply range)

Ordering & documentation

Documents

Shipments of U-Bolts by Pipe Size (IFI-136 Waterworks Series) are backed by Mill Test Certificate (MTC), Dimensional Report, Salt Spray Test Report on request, with full batch traceability from raw material to finished product. Quality management for U-Bolts by Pipe Size (IFI-136 Waterworks Series) orders follows the owner-confirmed compliance list: ISO 9001:2015, RoHS, REACH. Exact document sets are confirmed on the order.

Quotation

  • The product family (U-Bolts by Pipe Size (IFI-136 Waterworks Series)), product standard/designation and drawing or part number.
  • The dimensions that apply to this part — such as size, pitch, length, thickness, fit, grip or groove geometry.
  • Material/grade, heat-treatment condition and surface finish, together with the service environment.
  • Quantity per size, delivery destination and required test or traceability documents.

Sample & supply

Supply source for U-Bolts by Pipe Size (IFI-136 Waterworks Series): own manufacturing plus qualified outsourcing (per the owner-confirmed scope of supply (own production plus outsourcing)).

Minimum order quantity for u-bolts by pipe size (ifi-136 waterworks series) is 1,000–10,000 pieces depending on size (applies to the standard sizes and finishes for u-bolts by pipe size (ifi-136 waterworks series); mixed, special or custom variants are quoted — final commercial terms per quotation) Stock items for u-bolts by pipe size (ifi-136 waterworks series) run 3–7 days. High-strength and custom parts for u-bolts by pipe size (ifi-136 waterworks series) run 15–25 days. Quantities or variants of u-bolts by pipe size (ifi-136 waterworks series) outside the standard range are confirmed at quotation.

Storage & shipping

U-Bolts by Pipe Size (IFI-136 Waterworks Series) are packed for export and shipped factory-direct to buyers in Europe, Asia, the Americas and the Middle East. Store u-bolts by pipe size (ifi-136 waterworks series) dry and protected until installation, and keep coated parts in their packaging until use; specific packing and preservation requirements can be stated on the order and confirmed at quotation.

Frequently asked questions

Why do supplier U-bolt charts disagree on the same pipe size?

Usually it is the measuring convention, not the part. The IFI-136 convention — followed by the collected chart — measures length from the bolt end to the inside of the bend and the hook as the clear distance between legs; other charts show both dimensions to centreline, which shifts every number by one leg radius. When quoting or cross-referencing, state the convention alongside pipe size, diameter, hook, length and thread length, and the discrepancy disappears. The same discipline applies to custom U-bolts: a drawing without the convention noted is the most common source of a bent bolt that does not fit its clamp.

What does an RFQ for U-bolts need to state?

Nominal pipe size is the anchor, but the four IFI-136 dimensions close the drawing: bolt diameter (1/4–1 in across this series), hook C, length L and thread length T, each in the IFI-136 or centreline convention stated explicitly. Add thread series once confirmed, material and finish for the environment (waterworks hardware is commonly galvanized or stainless — grade confirmed at quotation), nut quantity per leg and any certificate requirement such as a mill test report per EN 10204 3.1. Sizes outside the standard ladder are quoted to drawing.

What is the MOQ and lead time for U-bolts?

The minimum order quantity for U-Bolts by Pipe Size (IFI-136 Waterworks Series) is 1,000–10,000 pieces depending on size. Stock items of U-Bolts by Pipe Size (IFI-136 Waterworks Series) ship in 3–7 days; high-strength and custom parts in 15–25 days. Confirm the exact schedule against quantity and pipe-size mix at quotation.

Request a Quote

Get factory-direct pricing from the manufacturer.

What to include in your U-Bolts by Pipe Size (IFI-136 Waterworks Series) inquiry

  • ✓ Name the bolt standard and product form, then give nominal diameter, pitch, length and threaded length.
  • ✓ State the applicable property class or material grade, head style, and coating or finish.
  • ✓ Identify the mating nut/washer and the joint duty; include any specified preload, tightening method or friction condition.
  • ✓ Give quantity per size, destination and required material or inspection certificates.
  • ✓ Factory-direct pricing for your U-Bolts by Pipe Size (IFI-136 Waterworks Series)
  • ✓ Standard and custom specifications
  • ✓ Factory-direct export to buyers in Europe, Asia, the Americas and the Middle East
  • ✓ Full fastener family support

We use your details only to answer this inquiry — see our Privacy notice for everything the form collects.