ISO Tolerance Zones (Shaft and Hole)
ISO system tolerance zones in millimetres for the nominal dimension steps — external (shaft) zones m6 and h6 through h16, internal (hole) zones H7 through H14 — tabulated over/to from 0 up to 120 mm, the workhorse zones for fastener-adjacent machining: pins, drilled and reamed holes, slot and keyway widths.
Last updated: 2026-11
Specifications
Fastener work lives next to the ISO fit system: a dowel pin is h6 or m6 on its outside, the hole it presses into is H7, a clearance slot is h14-width, and the drawings spell those zones as bare letter-number codes whose actual millimetre limits most people have to look up. This chart is that lookup, in the two tables the source prints: external measurements (shafts, pins, keys) with zones m6, h6, h8, h10, h11, h13, h14, h15, h16, and internal measurements (holes) with H7, H8, H9, H11, H13, H14 — each over/to nominal step from 0 through 120 mm showing the tolerance zone in mm exactly as the source prints the pair (e.g. m6 over 1 to 3: +0.002 +0.008; H7 over 3 to 6: +0.012 0). Read the lowercase zones as external (material outside the limit — a pin's diameter varies inside its zone) and uppercase as internal; m6 is the transition zone that makes a dowel a light press fit, h6 the precision clearance or line-to-line fit, and the coarse h-numbers the general sheet-metal and slot tolerances. The zones tabulated here are the fastener-adjacent selection, not the whole ISO 286 catalogue — other zones and larger dimension steps are quoted per RFQ against the standard. Where the drawing gives the fit code, this chart gives the mm; where it gives only mm, the fit code decision belongs to the designer.
| External table | Zones m6, h6, h8, h10, h11, h13, h14, h15, h16 over/to steps 0-1, 1-3, 3-6, 6-10, 10-18, 18-30, 30-50, 50-80, 80-120 mm; limits as printed, e.g. h6 over 6-10: 0 -0.009 |
|---|---|
| Internal table | Zones H7, H8, H9, H11, H13, H14 over the same steps; limits as printed, e.g. H7 over 10-18: +0.018 0 |
| Convention | Lowercase = external measurements (shafts/pins/keys); uppercase = internal measurements (holes); each cell prints the two limits, e.g. m6 '+0.002 +0.008' |
| Blank cells | h14-h16 not tabulated for the 0-1 mm step, H14 not tabulated for 0-1 mm — as printed |
| Not tabulated | Other ISO 286 zones (p6, n6, k6, e7...), steps beyond 120 mm, IT grade definitions — per the standard, quoted per RFQ |
| Nominal Dimension | Tolerance Zone in mm (External Measurements) | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| over | to | m6 | h6 | h8 | h10 | h11 | h13 | h14 | h15 | h16 |
| 0 | 1 | +0.002 +0.008 | 0 -0.006 | 0 -0.014 | 0 -0.040 | 0 -0.060 | 0 -0.14 | |||
| 1 | 3 | +0.002 +0.008 | 0 -0.006 | 0 -0.014 | 0 -0.040 | 0 -0.060 | 0 -0.14 | 0 -0.25 | 0 -0.40 | 0 -0.60 |
| 3 | 6 | +0.004 +0.012 | 0 -0.008 | 0 -0.018 | 0 -0.048 | 0 -0.075 | 0 -0.18 | 0 -0.30 | 0 -0.48 | 0 -0.75 |
| 6 | 10 | +0.006 +0.015 | 0 -0.009 | 0 -0.022 | 0 -0.058 | 0 -0.090 | 0 -0.22 | 0 -0.36 | 0 -0.58 | 0 -0.90 |
| 10 | 18 | +0.007 +0.018 | 0 -0.011 | 0 -0.027 | 0 -0.070 | 0 -0.110 | 0 -0.27 | 0 -0.43 | 0 -0.70 | 0 -1.10 |
| 18 | 30 | +0.008 +0.021 | 0 -0.030 | 0 -0.033 | 0 -0.084 | 0 -0.130 | 0 -0.33 | 0 -0.52 | 0 -0.84 | 0 -1.30 |
| 30 | 50 | 0 -0.39 | 0 -0.62 | 0 -1.00 | 0 -1.60 | |||||
| 50 | 80 | 0 -0.46 | 0 -0.74 | 0 -1.20 | 0 -1.90 | |||||
| 80 | 120 | 0 -0.54 | 0 -0.87 | 0 -1.40 | 0 -2.20 |
| Nominal Dimension | Tolerance Zone in mm (Internal Measurements) | ||||||
|---|---|---|---|---|---|---|---|
| over | to | H7 | H8 | H9 | H11 | H13 | H14 |
| 0 | 1 | +0.010 0 | +0.014 0 | +0.025 0 | +0.060 0 | +0.14 0 | |
| 1 | 3 | +0.010 0 | +0.014 0 | +0.025 0 | +0.060 0 | +0.14 0 | +0.25 0 |
| 3 | 6 | +0.012 0 | +0.018 0 | +0.030 0 | +0.075 0 | +0.18 0 | +0.30 0 |
| 6 | 10 | +0.015 0 | +0.022 0 | +0.036 0 | +0.090 0 | +0.22 0 | +0.36 0 |
| 10 | 18 | +0.018 0 | +0.027 0 | +0.043 0 | +0.110 0 | +0.27 0 | +0.43 0 |
| 18 | 30 | +0.021 0 | +0.033 0 | +0.052 0 | +0.130 0 | +0.33 0 | +0.52 0 |
| 30 | 50 | +0.39 0 | +0.62 0 | ||||
| 50 | 80 | +0.46 0 | +0.74 0 | ||||
| 80 | 120 | +0.54 0 | +0.87 0 |
Materials
- Tolerance zones are geometry, independent of material — but the fit behaviour is not: a given H7/m6 press behaves differently in aluminum than in steel (differential thermal expansion, embedment). We supply dowel pins, parallel keys and precision fasteners in the zones tabulated here with inspection certificates; fit-zone selection on the drawing is confirmed with the designer where material couples into the fit
Ordering & documentation
Documents
Shipments of ISO Tolerance Zones (Shaft and Hole) are backed by Mill Test Certificate (MTC), Dimensional Report, Salt Spray Test Report on request, with full batch traceability from raw material to finished product. Quality management for ISO Tolerance Zones (Shaft and Hole) orders follows the owner-confirmed compliance list: ISO 9001:2015, RoHS, REACH. Exact document sets are confirmed on the order.
Quotation
- The product family (ISO Tolerance Zones (Shaft and Hole)), product standard/designation and drawing or part number.
- The dimensions that apply to this part — such as size, pitch, length, thickness, fit, grip or groove geometry.
- Material/grade, heat-treatment condition and surface finish, together with the service environment.
- Quantity per size, delivery destination and required test or traceability documents.
Sample & supply
Minimum order quantity for iso tolerance zones (shaft and hole) is 10,000 pieces (applies to the standard sizes and finishes for iso tolerance zones (shaft and hole); mixed, special or custom variants are quoted — final commercial terms per quotation) Stock items for iso tolerance zones (shaft and hole) run 3–7 days. Quantities or variants of iso tolerance zones (shaft and hole) outside the standard range are confirmed at quotation.
Storage & shipping
ISO Tolerance Zones (Shaft and Hole) are packed for export and shipped factory-direct to buyers in Europe, Asia, the Americas and the Middle East. Store iso tolerance zones (shaft and hole) dry and protected until installation, and keep coated parts in their packaging until use; specific packing and preservation requirements can be stated on the order and confirmed at quotation.
Frequently asked questions
What is the practical difference between an h6 and an m6 dowel pin?
Both are precision pins within a couple of microns over most steps — the difference is where the zone sits relative to nominal. h6 sits at or just under nominal (over 6-10 mm: 0 to -0.009), so an h6 pin in an H7 hole is a snug slide or line-to-line location fit that comes back apart. m6 sits just over nominal (over 6-10 mm: +0.015 to +0.006 per the chart's external table), so m6 into H7 is a light interference — a press fit that locates positively and resists falling out under vibration, at the cost of needing an arbor press and giving up easy disassembly. The selection is the designer's (driven by whether the pin ever needs to come out and what loads it sees); this chart's job is the numbers once the code is on the drawing. The practical caution: do not swap pin codes in the field to cure a loose fit — an m6 pin in a hole machined for h6 assembly can split a thin boss.
Why does the chart stop at 120 mm and skip zones like e7 or p6?
Because the source tabulates the fastener-adjacent selection: the zones that dominate fastener, pin, key and general machining callouts on hardware-sized work, over the dimension steps where those parts live. The full ISO 286 system defines a large grid of zones across many more steps — bearing fits (e7, g6), heavy press fits (p6, s6) and large-diameter work all exist but belong to machine-design territory rather than fastener-adjacent lookup. If your drawing carries one of those, it is still a normal quotation: send the fit code and dimension, and the limits are read from the standard rather than from this page. The same applies past 120 mm — the chart's over/to ladder ends where the tabulated source ends, not where the system does. Treat this page as the day-to-day lookup and the standard as the governing document; acceptance always follows the drawing's stated zone in mm or code.
What is the MOQ and lead time for ISO Tolerance Zones (Shaft and Hole)?
Orders under this designation have a minimum order quantity of 10,000 pieces. Stock items ship in 3–7 days. Final commercial terms are confirmed per quotation.
What should an RFQ for ISO Tolerance Zones (Shaft and Hole) state?
State the full designation (ISO Tolerance Zones (Shaft and Hole)), thread size and pitch or diameter, length or head dimension, finish, quantity per size, plus the destination country and any required certificate such as a mill test report per EN 10204 3.1; dimensions and schedule for this designation are confirmed with the quotation.
Related knowledge
- Thread-Forming vs Thread-Cutting vs Thread-Rolling Self-Tapping Screws: What the Evidence Settles on Base Material
- Screw Family Selection by Base Material: Wood, Machine and Self-Tapping Threads, Engagement and Coating
- Hex Bolts vs Socket Head Cap Screws: What the Evidence Settles on Strength, Clearance and Cost
Request a Quote
Get factory-direct pricing from the manufacturer.
What to include in your ISO Tolerance Zones (Shaft and Hole) inquiry
- ✓ Identify the screw type and standard, including head style and drive recess.
- ✓ Give nominal diameter, thread pitch, length and engagement or hole details where relevant.
- ✓ State the material/property class, substrate material and thickness, and required coating or finish.
- ✓ Describe installation, locking or removal requirements, quantity and destination.
- ✓ Factory-direct pricing for your ISO Tolerance Zones (Shaft and Hole)
- ✓ Standard and custom specifications
- ✓ Factory-direct export to buyers in Europe, Asia, the Americas and the Middle East
- ✓ Full fastener family support